DDORF WOHNEN
Guide · Buy & Build

Calculating GRZ and GFZ: site coverage ratio, floor area ratio and wGFZ

Updated on 31 October 2026 · 9 min read

How large may a house on a plot be? The answer is usually in the development plan (Bebauungsplan), expressed as the site coverage ratio (GRZ) and the floor area ratio (GFZ). This guide explains the terms of the Land Use Ordinance (BauNVO), calculates the permitted footprint and floor area for your plot and shows where to find the development plan in Düsseldorf.

Illustration (AI generated): Rhine promenade with the Rheinturm and Rheinkniebrücke · stylised from a photo reference

Brief answers

  • Permitted footprint = GRZ times the relevant plot area. Example: 500 m² times a GRZ of 0.4 gives 200 m² for the building.
  • Garages, parking spaces with their driveways and ancillary structures may exceed the permitted footprint by up to 50%, but at most up to a GRZ of 0.8 (Section 19(4) BauNVO). In the example, that is up to 300 m² in total.
  • Permitted floor area = GFZ times the plot area. With 500 m² and a GFZ of 0.8, all full stories together may have 400 m², measured by external dimensions (Section 20 BauNVO).
Content · Sections: 9
  1. 01GRZ, GFZ and full story: the terms of the BauNVO
  2. 02Calculating the site coverage ratio: formula and example
  3. 03Calculating the floor area ratio and determining the floor area
  4. 04GRZ and GFZ calculator
  5. 05Upper limits under Section 17 BauNVO: guide values
  6. 06Finding the development plan in Düsseldorf
  7. 07Without a development plan: Section 34 BauGB in built-up areas
  8. 08Calculating the wGFZ: value-relevant floor area ratio for the standard land value
  9. 09Calculating the pitch angle: converting degrees to percent

By Serhii Panchenko · Software development and editorial work. General information, not advice on your individual circumstances.

01GRZ, GFZ and full story: the terms of the BauNVO

The degree of building use is governed by Sections 16 to 21a of the Land Use Ordinance (BauNVO). A development plan must always set the site coverage ratio or the size of the footprints (Section 16(3) BauNVO). It often also sets the floor area ratio, the number of full stories or the height of structures.

Degree of building use under the BauNVO

Term
Site coverage ratio (GRZ)
Meaning
Square meters of footprint per square meter of plot area (Section 19(1))
Term
Permitted footprint
Meaning
Share of the building plot that may be covered by structures (Section 19(2))
Term
Floor area ratio (GFZ)
Meaning
Square meters of floor area per square meter of plot area (Section 20(2))
Term
Floor area
Meaning
Area of all full stories by external dimensions (Section 20(3))
Term
Full story (Vollgeschoss)
Meaning
Defined by state law (Section 20(1)); in North Rhine-Westphalia by Section 2(6) BauO NRW
Term
Building volume ratio (BMZ)
Meaning
Cubic meters of building volume per square meter of plot area (Section 21(1))
Source: Sections 16, 19, 20, 21 Land Use Ordinance (BauNVO) · As of 10/2026

The relevant area is not always the entire area recorded in the land register. For GRZ and GFZ, what counts is the area of the building plot that lies within building land and behind the street boundary line set in the development plan (Section 19(3) BauNVO). If no street boundary line is set, the area behind the actual street boundary counts.

Special rules for garage stories, shared facilities and covered parking spaces are in Section 21a BauNVO. They usually apply only if the development plan sets them or provides for them as an exception.

02Calculating the site coverage ratio: formula and example

The formula is simple: permitted footprint equals GRZ times the relevant plot area. Conversely, the built-over area divided by the plot area gives the existing GRZ. A 500 m² plot with a GRZ of 0.4 may be built on with a footprint of 200 m².

The footprint also includes garages and parking spaces with their driveways, ancillary structures within the meaning of Section 14 BauNVO and underground structures that merely extend beneath the plot, such as an underground garage (Section 19(4) sentence 1 BauNVO). These structures may exceed the permitted footprint by up to 50%, but at most up to a GRZ of 0.8.

Examples of the upper limit under Section 19(4) BauNVO
GRZ in the development planGRZ including garages and ancillary structures
0,20,3
0,40,6
0,60,8
Source: Section 19(4) sentence 2 Land Use Ordinance (BauNVO) · As of 10/2026

The development plan may deviate from this rule. Further minor exceedances may be permitted. The building authority decides whether that is possible in an individual case.

Good to know

The main building alone generally has to stay within the permitted footprint. The 50% exceedance applies only to garages, parking spaces, driveways, ancillary structures and underground structures.

03Calculating the floor area ratio and determining the floor area

The permitted floor area is the GFZ times the relevant plot area. With 500 m² and a GFZ of 0.8, all full stories together may have 400 m² of floor area. It is measured by external dimensions, so including the exterior walls (Section 20(3) BauNVO).

Ancillary structures, balconies, loggias and terraces are not included, nor are structures permitted in the setback areas under state law (Section 20(4) BauNVO). Stories that are not full stories generally do not count. However, the development plan may stipulate that habitable rooms on other stories are to be included in whole or in part.

  1. 1Identify the storiesFor each above-ground story, check whether it is a full story under Section 2(6) BauO NRW.
  2. 2Use external dimensionsMeasure the area of each full story by the building's external dimensions, not by the living area.
  3. 3Add them upAdd up the areas of all full stories. The result is the floor area.
  4. 4Compare with the GFZDivide the floor area by the relevant plot area and compare the result with the GFZ in the development plan.

In North Rhine-Westphalia, full stories are above-ground stories with a clear height of at least 2.30 m. A story is a full story only if it has this height over more than three quarters of the floor area of the story below (Section 2(6) BauO NRW). A story is above ground if the top of its ceiling projects on average more than 1.60 m above ground level (Section 2(5) BauO NRW).

Good to know

An attic story with sloping ceilings is therefore often not a full story and then does not count toward the floor area. The floor area is not the living area: it is measured by external dimensions and has no half-counting rule.

04GRZ and GFZ calculator

Enter the relevant plot area and the values from the development plan. With the areas of your plans, the calculator shows whether the GRZ, the upper limit under Section 19(4) BauNVO, the GFZ and the number of full stories are complied with. Below, it converts pitch angles from degrees to percent and vice versa.

GRZ and GFZ calculatorYour calculation
Plot and development plan
Your plans

Enter the plot area and GRZ – the result appears immediately.

Simplified calculation: the development plan may deviate from Section 19(4) BauNVO, count additional areas or allow exceptions. The calculator does not check building boundaries, building lines, setback areas or building heights. The building authority makes the binding decision. Your entries do not leave this page.

Convert pitch angle: degrees and percent

Enter a pitch angle.

05Upper limits under Section 17 BauNVO: guide values

Section 17 BauNVO sets guide values for upper limits for each building zone. They are benchmarks for the municipality's planning, not rigid limits. Only in weekend home areas and holiday home areas may they not be exceeded.

Guide values for upper limits under Section 17 BauNVO

Building zone
Small settlement areas
GRZ
0,2
GFZ
0,4
Building zone
Purely residential and general residential areas, holiday home areas
GRZ
0,4
GFZ
1,2
Building zone
Special residential areas
GRZ
0,6
GFZ
1,6
Building zone
Village areas, mixed-use areas, village residential areas
GRZ
0,6
GFZ
1,2
Building zone
Urban areas
GRZ
0,8
GFZ
3,0
Building zone
Core areas
GRZ
1.0
GFZ
3,0
Building zone
Commercial areas, industrial areas, other special areas
GRZ
0,8
GFZ
2,4
Building zone
Weekend home areas
GRZ
0,2
GFZ
0,2
Source: Section 17 Land Use Ordinance (BauNVO) · As of 10/2026

For your plot, the values in the development plan apply, not the table. The ordinance was amended in 2021 in connection with the Building Land Mobilization Act (Baulandmobilisierungsgesetz). For development plans whose draft was publicly displayed before June 23, 2021, the version of the ordinance in force until then applies (Section 25e BauNVO). Older plans may also refer to earlier versions of the BauNVO.

06Finding the development plan in Düsseldorf

The development plan sets the type and degree of building use and the areas of the plot that may be built on in a binding way. It shows which use, how many stories and what building density apply to a plot. The City of Düsseldorf makes its development plans available online.

  1. 1Open Düsseldorf MapsOn the urban planning office's page, the link “Alle Bebauungspläne bei Düsseldorf Maps” (all development plans in Düsseldorf Maps) leads to the city's geoportal.
  2. 2Find the plotSearch for the address and check whether the plot lies within the area covered by a development plan.
  3. 3Read the provisionsThe plan usually states the building zone, GRZ, GFZ and the number of full stories. Building boundaries and building lines show the area that may be built on.
  4. 4Check the written provisionsDeviations from the BauNVO, for example on how garages or attic stories are counted, are often in the written part of the plan.

For plans since 2008, there is also an overview map of land-use plans. The urban planning office publishes ongoing procedures and development freezes (Veränderungssperren) separately. If anything is unclear, ask the urban planning office or the building authority.

07Without a development plan: Section 34 BauGB in built-up areas

If a plot is in a built-up area without a development plan, Section 34 BauGB applies: a project is permissible if it fits into the character of the immediate surroundings in terms of type and degree of building use, building style and the plot area to be built on, and if access and utilities are secured.

In that case there is no fixed GRZ or GFZ. The building authority generally compares your project with the existing buildings in the area, for example in terms of footprint, height and number of stories. Here, the calculator only helps you compare the values of neighboring houses with your plans.

Good to know

Before submitting a building application, you can have individual questions clarified with a preliminary decision (Vorbescheid) (Section 77 BauO NRW). The preliminary decision is valid for three years. If it concerns a building, the submission documents must be prepared by a person authorized to submit building plans.

08Calculating the wGFZ: value-relevant floor area ratio for the standard land value

The value-relevant floor area ratio (WGFZ) does not come from building law but from the Real Estate Valuation Ordinance (ImmoWertV). For the reference plot of a standard land value, the degree of building use is stated if it affects the value (Section 16(2) ImmoWertV). A WGFZ can be given for this purpose.

Determining the WGFZ under Section 16(4) ImmoWertV
Storycounted
All above-ground stories by external dimensionsin full
Setback storyin full
Finished attic story or one that can be finished75%
Attic story that cannot be finishednot at all
Void where habitable rooms are not possiblenot a story
Source: Section 16(4) Real Estate Valuation Ordinance (ImmoWertV) · As of 10/2026

For the WGFZ, a story is above ground if the top of its ceiling projects on average more than 1.40 m above ground level. Whether it is a full story does not matter. The sum of the areas divided by the plot area gives the WGFZ.

If the WGFZ of your plot differs from that of the reference plot, appraisers generally account for the difference using conversion coefficients (Section 19 ImmoWertV). Conversion coefficients are derived from suitable purchase prices. The responsible valuation committee (Gutachterausschuss) can tell you which ones fit your plot.

09Calculating the pitch angle: converting degrees to percent

Roof pitches in development plans are often given in degrees, driveway gradients often in percent. The conversion follows from trigonometry: percent equals the tangent of the angle times 100. Conversely, the angle is the arctangent of the percent divided by 100.

Pitch: degrees and percent
DegreesPercent
5°8.75%
15°26.79%
30°57.74%
45°100%
60°173.21%
Source: own calculation, percent = tan(angle) × 100

To calculate the pitch from measurements: the difference in height divided by the horizontal length times 100 gives the percent. A roof that rises 2 m over a horizontal length of 4 m has a 50% pitch, which is about 26.57 degrees.

Frequently asked questions

F-01

How do you calculate the site coverage ratio (GRZ)?

Built-over footprint divided by the relevant plot area. Conversely, the permitted footprint is the GRZ times the plot area, so 200 m² for 500 m² and a GRZ of 0.4.

F-02

How do you calculate the floor area ratio (GFZ)?

The sum of the areas of all full stories by external dimensions divided by the relevant plot area. Balconies, loggias, terraces and ancillary structures do not count (Section 20 BauNVO).

F-03

Do a garage and a terrace count toward the GRZ?

Garages, parking spaces with driveways and ancillary structures count toward the footprint. However, they may exceed the permitted footprint by up to 50%, at most up to a GRZ of 0.8 (Section 19(4) BauNVO). Whether a terrace counts depends on how it is built and on the development plan.

F-04

What is a full story (Vollgeschoss) in NRW?

An above-ground story with a clear height of at least 2.30 m over more than three quarters of the floor area of the story below (Section 2(6) BauO NRW).

F-05

What is the wGFZ?

The value-relevant floor area ratio under Section 16(4) ImmoWertV. It counts all above-ground stories, with finished attic stories or those that can be finished at 75%, and is used by valuation committees for standard land values.

F-06

How do you convert degrees to percent?

Percent equals the tangent of the angle times 100. 30 degrees is about 57.74%, 45 degrees exactly 100%.

No legal or tax advice

This guide provides a general overview and does not replace legal or building advice. The development plan, applicable building law and the decision of the building authority are authoritative.

Next steps and background

Data sources

Official source · Our own calculation · Our own analysis · DDORF estimate → Methodology

As of · Legal information: 10/2026 · Source: DDORF WOHNEN editorial team